Specifications — MHR-5STP-2 Cable
UL NEC/
C(UL) CEC
UL AWM
Temp.
Standard
Lengths Weights
Shipping Conductor
Nominal
Core OD
Shielding
Materials
(% coverage)
Nom. DCR
Nominal
OD
Nominal
Capacitance
Nominal
Attenuation
Description
Nom.
Vel.
of
No.
of
Cond.
Nom.
Imp.
(ohms)
(stranding)
Diameter
Nom. DCR
Part No. (length)
Model
dB/
dB/
MHz
Prop.
Ft.
m
Lbs. kg
Inch mm
Inch mm
pF/ft pF/m
100 ft 100 m
Composite: (5) 26 AWG Miniature Coax • (2) 22 AWG Shielded Twisted Pairs • Coax Shielding: Aluminum Foil (100%) + Tinned Copper Serve
Nonplenum Cable • Gas-injected Foamed Polyolefin Insulation • PVC Inner Jackets • Gray PVC Outer Jacket
1
5
10
20
50
-0.5
-1.2
-1.7
-2.4
-3.8
-4.5
-5.4
-6.3
-7.3
-7.7
-9.1
-11.5
-16.4
-19.5
-43.6
-1.7
-3.9
-5.5
26 AWG
(7/34)
0.019"
Alum. Foil
(100%)
5
coax
0.072 1.83
75
81%
16.7
54.8
500 152.4 42 19.1
304.8
Single:
22-175-02 (500')
22-175-03 (1000')
0.105 2.67
red, green, blue,
black, yellow
1000
83 37.6
Tinned Cu
Serve (95%)
-7.8
MHR-5STP-2
0.48 mm,
-12.3
-14.8
-17.6
-20.6
-23.9
-25.4
-29.9
-37.3
-53.8
-64.0
-143.0
Tinned Cu
12.2 ohms/
1k ft,
40.0 ohms/
1 km
71
100
135
180
200
270
400
750
1000
3000
41 ohms/
1k ft,
135 ohms
1 km
NEC CM
UL 1581
CSA FT-4
Sweep tested 5 MHz to 1 GHz.
66% 35 115
22 AWG
(7/30)
0.030"
Alum. Foil
(100%)
Single:
2
shielded
twisted
pairs
0.046 1.2
red and black,
green and white
conductor-
conductor
60 °C
17 ohms/
1k ft,
56 ohms/
1 km
0.76 mm,
Tinned Cu
62
203
Min. bend radius: 4.0"
17 ohms/
1k ft,
56 ohms
1 km
conductor-
conductor,
connected to
shield
Overall:
Overall
cable
0.400 10.2
gray
Plenum Cable • Gas-injected Foamed FEP Insulation • Fluorocopolymer Inner Jackets • Blue Fire-resistant PVC Outer Jacket
38
1
5
10
20
50
-0.5
-1.2
-1.7
-2.4
-3.8
-4.5
-5.4
-6.3
-7.3
-7.7
-9.1
-11.5
-16.4
-19.5
-43.6
-1.7
-3.9
-5.5
152.4
26 AWG
(7/34)
0.019"
Alum. in
Polyester Tape
(100%)
500
17.2
5
coax
0.074 1.88
75
81%
16.7
54.8
Single:
22-181-02 (500')
22-181-03 (1000')
0.102 2.59
red, green, blue,
black, yellow
1000 304.8 75 34.0
-7.8
MHR-5STP-2P
0.48 mm,
Tinned Cu
Serve (95%)
-12.3
-14.8
-17.6
-20.6
-23.9
-25.4
-29.9
-37.3
-53.8
-64.0
-143.0
Tinned Cu
71
100
135
180
200
270
400
750
1000
3000
41 ohms/
1k ft,
135 ohms
1 km
12.2 ohms/
1k ft,
40.0 ohms/
1 km
NEC CMP
UL 910
CSA FT-6
Sweep tested 5 MHz to 1 GHz.
66% 35 115
22 AWG
(7/30)
0.030"
Alum. in
Polyester Foil
(100%)
Single:
2
shielded
twisted
pairs
0.046 1.2
red and black,
green and white
with gray
fluorocopolymer
jacket
60 °C
conductor-
conductor
0.76 mm,
17 ohms/
1k ft,
56 ohms/
1 km
Tinned Cu
62
203
Min. bend radius: 7.0"
17 ohms/
1k ft,
56 ohms
1 km
conductor-
conductor,
connected to
shield
for each pair
Overall:
0.350 8.9
blue
02 December, 2008
|
Edimax Technology Network Card HP 5102 User Manual
Edimax Technology Switch ES 3116RE+ User Manual
Escali Scale Pana User Manual
Extron electronic Switch FOX T USW 103 User Manual
Fellowes Paper Shredder FS 3 User Manual
Fender Speaker CHAMPION 20 User Manual
Gamber Johnson Laptop Docking Station CF53 User Manual
Gefen Portable Generator GTB HD SIGGEN User Manual
GE Monogram Refrigerator ZDOD240 User Manual
GE Washer DSKS333 User Manual