EXP Computer Network Card PCMCIA Ethernet Modem Adapter User Manual

ThinCom PCMCIA  
Ethernet - Modem  
Adapter  
User=s Manual  
- i -  
 
TABLE OF CONTENTS  
INTRODUCTION  
Features and Compatibility.............................................................. 1  
REQUIREMENTS  
Notebook computer with PC Card slot............................................ 2  
PC Card device driver...................................................................... 2  
Upper Memory Block Region........................................................... 2  
Analog Telephone line..................................................................... 2  
INSTALLATION  
Hardware Installation ...................................................................... 5  
Software Installation......................................................................... 7  
Diagnose the need for PC Card (PCMCIA 2.10) software.............................support.7  
Installing the PointEnabler Device Driver............................... 9  
Installing the PointEnabler Device Driver on an unlisted................  
Host PC.  
10  
Installation Verification................................................................... 11..............Windows 95 Installation for Modem  
Enabling 32-bit card support of Windows 95................................ 13  
12  
Modem Selection........................................................................... 15  
DATA COMMUNICATION.......................................................................... 15  
Operating Mode.............................................................................. 17  
CELLULAR OPERATION.......................................................................... 19  
FAX OPERATION....................................................................................... 20  
DIAGNOSTIC FUNCTION......................................................................... 21  
TROUBLE SHOOTING.............................................................................. 23  
APPENDIX A  
AT Commands for 28,800............................................................. 24  
AT Command for 1414CL............................................................. 31  
TABLE OF CONTENTS (Cont.)  
- iii-  
 
AT Command for 2400, 96,00 and 33,600/14,400....................... 37  
APPENDIX B  
S Register Summary......................................................41  
FCC Compliance Statements.................................................................... 45  
FCC Part 68................................................................................................ 45  
FCC Part 15................................................................................................ 46  
Canadian Department of Communication Compliance Statemen.t......... 47  
- iv -  
 
INTRODUCTION  
INTRODUCTION  
Congratulation on your purchase of the ThinCom PC Card. It is among the finest card in today's market. We develop this innovative product to meet or exceed the computer manufacturers' specifications as  
well as your communication needs.  
The ThinCom has dual functions in one card, the Fax/Data Modem portion allows you to use data communication such as connecting to an on-line service or the Internet, or send and receive fax. Ethernet  
Local Area Network portion give you the connection to your LAN server. These two functions can be performed simultaneously. For example down load a file from a remote location to a network drive.  
Features  
!
!
!
!
Dual functions Data/Fax modem and Ethernet in a Type II PC Card  
Simultaneous modem and Ethernet Local Area Network operation.  
Compatible with standard Socket Services and Card Services (PCMCIA 2.1) and Windows 95.  
3 years warranty  
Fax/Data Modem  
!
!
!
!
!
!
Support industrial standard Hayes "AT" command set  
Adaptive Dialing  
Call progress monitoring  
Data Mode communication speed: 33,600, 28,800, 14,400, 9600 or 2400 bps  
Compatible protocol: ITU (CCITT) V.34, V.FC, V.32bis, V.32, V.23, V.22bis, V.22, V22.A/B, V.21, Bell 103 and 212A.  
Fax Mode: Group III Compatible  
Class I and/or Class II commands on send and receive up to 14,400 bps  
ITU (CCITT) V.17, V.29, V.27ter, V.21 Ch.2  
Built-in Error correction: V.42, MNP 2-4  
Built-in Data Compression: V.42 bis and MNP 5  
Automatic Power Save in sleep mode  
Auto Retrain  
Support Diagnostics modes  
Cellular ready using MNP 10 Cellular Enhancement protocol  
!
!
!
!
!
!
Ethernet  
!
!
!
Support IEEE 802.3 (ANSI 8802-3) and Ethernet Standard.  
Direct 10 Base T (twisted pair) connection using RJ-45  
Driver support for most Network Operating System  
SYSTEM REQUIREMENT  
The following list contains all elements needed for the ThinCom PC Card to function as a fax/data modem and Ethernet card.  
1. A notebook or desktop computer with a PC Card (PCMCIA ) slot.  
- 1 -  
 
INTRODUCTION  
The system should have at least one Type II or Type III (5.0 mm or 10.0 mm thickness) slot.  
2. DOS version 5.0 or higher  
Or  
Windows 95  
3. Socket Service and Card Service compliant with PCMCIA 2.10 to operate the  
PC Card (PCMCIA ) slot.  
Normally, the device driver is pre-installed on the computer from the factory.  
4. Network operating system software compatible with NDIS or ODI drivers.  
5. A RJ-45 (10 Base-T) jack connect to a network server or a computer.  
6. A working analog telephone line  
- 2 -  
 
INSTALLATION  
INSTALLATION  
Before you begin the installation procedure, check and verify content of the ThinCom package. If you are missing any of the items listed below, please contact your dealer.  
!
!
!
!
!
!
ThinCom PC Card  
Device driver and Diagnostics diskette  
This User's Manual  
Diskette and manual for data and fax communications software  
Telephone line interface cable with RJ-11 modular plug  
Ethernet 10 Base T interface cable with RJ-45 modular plug for network opration  
Before You Begin  
CAUTION! The electronic components and IC chips installed on the ThinCom card are very sensitive to damage  
metal surface.  
from static electricity. Before touching the card, touch a grounded  
-
-
Inspect the ThinCom card for any damage which may have occurred during shipping. If any damage is found, please notify your dealer immediately for prompt replacement.  
Turn off the computer  
HARDWARE INSTALLATION GUIDE  
This section provides you with general information on how to install the PC Card into the majority of notebook computers available on the market today.  
1. Locate the PCMCIA slot, which is usually on one side of the computer. Some PCMCIA system allows "hot insertion" (inserting the card while PC power still on). Consult your computer User's  
manual for detail. If you are in doubt, turn the power off.  
2. Align the ThinCom card with the arrow sign pointing to the computer's slot. (Please note that the card is keyed to guide for proper installation.)  
Hardware Installation Guide(Cont.)  
3. Slowly insert card into a slot and press firmly until the ThinCom card connector is seated.  
4. Insert the telephone line interface cable with RJ-11 connector into the Fax/Data modem port (Black connector). Push in the connector firmly.  
- 3 -  
 
INSTALLATION  
Make sure to match the cable connector=s color with the connector on the card. The Modem connector is keyed, and it can not be inserted to the Ethernet connector accidently.  
5. Insert the LAN interface cable with RJ-45 connector into the LAN port  
(White connector). Push in the connector firmly.  
Make sure to match the cable connector=s color with the connector on the card. The Ethernet connector is keyed, and it can not be inserted to the Modem connector accidently.  
6. You are now ready to install the ThinCom=s Ethernet and Modem device driver.  
Please follow the Software Installation Guide procedures.  
SOFTWARE INSTALLATION GUIDE for DOS/Windows 3.XX  
Install theThinCom=s driver with PC Card device driver  
C
C
Most of the notebook computer manufacturers supply the device driver program to operate the PC Card slot on their computers. The ThinCom=s driver work with the PC Card (Socket Service and Card  
Service) device driver compliant to the PCMCIA 2.1 or later specification. Check the table on the APPENDIX A for the name of some widely used device drivers.  
A minimum of 8K block of memory in the UMB (Upper Memory Block) should be available. In order to initialize and access the ThinCom card such a memory block exclusion is requied. In most case the  
PC Card device driver installation program will set the option in the EMM386.exe of the C:\config.sys file. The statement may look like this: (The actul setting for your computer may be different)  
- 4 -  
 
INSTALLATION  
DEVICE=C:\DOS\EMM386.EXE NOEMS X=D000-DFFF  
C
Depending on the network environment, you need to choose whether you want to use ODI, NDIS2 or NDIS3 drivers. (These files are included with your installation diskette.) Use the following table as a  
guide:  
Network Environment  
Netware from DOS  
Netware from DOS and/or Windows 3.1x  
MS Windows Network from windows 3.1 x  
Netware and MS Windows Network Windows 3.1 x  
Lan Manager  
Driver selection  
ODI  
ODI  
NDIS (ODI also possible)  
ODI  
NDIS2  
Windows 95  
NDIS3 Miniport  
C
Insert the diskette into the floppy drive, at the DOS prompt type in >A:\install=, or from File Manager double click on >install.exe=. At the greeting screen press >Enter= to continue. A selection menu will display  
as the following:  
EXP ThinCom PCMCIA Modem/Net card - Installation Program  
[ X ] Full installation  
[
[
[
] Enabler ( No Card Service )  
] ODI  
] NDIS  
[Space] to toggle. [F2] or [Enter] to continue. [Esc] to quit.  
Full installation: This option install modem and Ethernet card device driver including Novell ODI and Microsoft NDIS network driver.  
Enabler:  
ODI:  
Choose this option to install the Novell=s network device  
Choose this option to install the Microsoft=s network device  
driver only.  
driver only.  
NDIS:  
Use the Up/Down Arrow key to move the cursor and the Space key to select the drivers to be installed. When ready to install, press Enter key to continue.  
C
C
The next screen prompt you to enter the location to install the device driver, please enter the target directory name, or press Enter key to accept the default directory.  
After the device drivers are copied in to the directory, screen will prompt to change the AUTOEXEC.BAT and CONFIG.SYS so the driver can take effect on the next system boot up. Please select Yes so  
the program can modify those files.  
C
The README.TXT file contain any recent change of the device driver, press the Enter key after the modification to the AUTOEXEC.BAT and CONFIG.SYS files. Or you may press the Esc key to exit the  
installation.  
NOTE: Remember to reboot the system so the newly installed device driver will take effect.  
INSTALLATION VERIFICATION  
MODEM  
- 5 -  
 
INSTALLATION  
PC Card (PCMCIA) device driver  
Most PC Card software will have a utility program to display the socket status,  
card type, card manufacturer name and system resource used by the PC Card inserted. These programs have a name such as >PCMINFO.EXE , CARDINFO.EXE, CARDVIEW or PCCARD.EXE  
etc..  
If the ThinCom card is recognized and configured successfully, the screen message will show socket(s) information, card type as modem together with the COM port and interupt request number  
assigned to the modem.  
NOTE: For DOS communication program user, make sure the Interupt Request number match the assigned number from PC Card device drivers.  
For Windows 3.xx, you need to set the COM port Interupt Request( Control Panel => Port => COM x => Advance => Setting) to match the assigned number from PC Card device drivers  
- 6 -  
 
INSTALLATION  
TESTING THE MODEM  
This section contains steps to verify the installation of the ThinCom Modem portion by using a communication software.  
1. Install and start a data communication software. (for Microsoft Windows users Click on Accessories Group => Terminal) Select terminal mode.  
2. In setup modem, set COM port to match COM Port previously set by the PC Card device driver  
3. Set Baud Rate, Data bits, Parity, Flow Control and Stop bit parameters to your normally use.  
4. Enter the terminal mode. This will allow you to issue the 'AT' command directly to the modem.  
5. Type 'AT' or 'at' then press ENTER key. (Note: the modem will not recognize mixed case such as 'At' or 'aT') The modem should respond with 'OK' on the screen. The modem=s active parameters  
may be reviewed by using the AT&V command.  
TESTING THE NETWORK  
On the next system reboot the EXPNET.BAT file will start and attempt to log in to a network.  
The THINCOM.EXE PC Card network adapter driver  
- 7 -  
 
INSTALLATION  
WINDOWS 95 INSTALLATION  
The ThinCom card is a Windows 95 compatible product. It is installed as Plug-N-Play peripheral. Your system >32-Bit PC Card (PCMCIA) support= should be enabled prior to operating the ThinCom card.  
(See >Enable the 32-Bit card support in Windows 95' next page) Be sure to have your ThinCom= s device driver diskette and the Windows 95 CD-ROM or diskette handy.  
INSTALL THE THINCOM CARD  
1. Start Windows 95 and insert the modem into PC Card (PCMCIA) slot. Check your computer User*s manual for the slot location.  
2. The Windows 95 will sense the new hardware upon a card insertion and ask you for the software driver diskette.  
3. Depending on the previous software and hardware installed in your system, it may attempt to copy other files from the Windows 95 install source (CD-ROM or diskette).  
NOTE: If you are reinstalling the card in a system where there is a previous version of the drivers for this card you must competely remove old entries from Control Panel => System => Device Manager =>  
Multi-Function Adapter.  
IF SOMETHING GOES WRONG  
In case of difficulty such as after you inserted the card and there is NO ANew Hardware Found@ window pop-up or there is no information about the modem. Please check the PCMCIA Socket  
support, the 32-Bit Card support may not enable or working properly. Follow the instruction to enabling the Socket support.  
- 8 -  
 
INSTALLATION  
ENABLING 32-BIT CARD SUPPORT IN WINDOWS 95  
To check whether your computer is PCMCIA Socket supported, first, double-click on the ASystem@ icon from AControl Panel@ folder (you can select the AControl Panel@ under ASettings@ from the AStart@ menu  
to open the AControl Panel@ folder).  
Click on the Device Manager Tab. If APCMCIA Socket@ has a cross (X) sign next to the PCMCIA Controller as show above, it means the PCMCIA device driver is not using 32-Bit Card Support. The socket(s)  
is not enabled at this time and there should be only one such a line displayed. In this case, double click on the PCMCIA Controller, and a dialog box will be displayed as below. Please place a check mark next  
to the current configuration of Device usage box, then select OK.  
After the PCMCIA 32-Bit Card support is installed, Windows will ask you to reboot your computer. Then you should repeat the install procedures.  
If the PCMCIA Socket is not found, then you must add a PCMCIA socket to your system. Please click on the AAdd New Hardware@ icon in the Control Panel folder and select APCMCIA socket@. Select the  
appropriate type of PCMCIA Controller that matches with yours system and follow the on-screen instructions.  
- 9 -  
 
INSTALLATION  
INSTALLATION VERIFICATION Cont.  
MODEM  
Windows 95  
After installation, you may wish to check if the computer recognized the modem and the assigned COM port.  
1. Click on Start => Settings => Control Panel => Modem => Diagnostics tab.  
2. Locate the modem*s COM port then highlight it. Click on >More Info...* button.  
3. The Windows 95 will try to communicate with the modem. The More Info... window appear with all the modem identification information. (Your actual display may be different)  
The ThinCom modem portion is installed properly and ready to use.  
- 10 -  
 
INSTALLATION  
NETWORK  
Go to > Control Panel= => Network and then install the nescessery network driver for the Windows 95. Also in here all the protocal driver are listed in here.  
Upon next restart of the notebook. The system will prompt for a network login.  
- 11 -  
 
INSTALLATION  
During the installation of the communication software you may be asked to select a model from a list of the support modem. Use the table below to help you with your selection.  
Modem speed (Data/Fax)  
Choose  
Or using the following  
Initialization string  
2400/9600  
Hayes Smart Modem  
Hayes V Series  
AT&F &C1 &D2  
9600/9600  
AT&F &C1 &D2 &K3 S48=7  
14,400/14,400  
Hayes Optima 14,400 + Fax  
AT&F W1 F0 &C1 &D2  
&K3 S48=7  
14,400/14,400CL  
28,800/14,400  
Hayes Ultra 14,400  
AT&F &C1 &D2  
Hayes Optima 28,800 + Fax  
AT&F W1 F0 &C1 &D2  
&K3 S48=7  
- 12 -  
 
DATA COMMUNICATION OPERATION  
The Fax/Data Modem may be used to connect to an On-Line service, local BBS (Bulletin Board System) or the Internet. This connection may require different communication parameters. The  
following parameters are the basic settings needed for a successful connection:  
1. Data Bit  
8 Data bit is the most common setting.  
7 Data bit some for On-Line service and mostly Main frame connection.  
2. Stop Bit  
3. Parity  
1 Stop bit is widely use.  
There are three setting: ODD, EVEN or NONE depends on the system you are trying to connect.  
The speed that the data traveling between the modem and your computer. The setting should be four times of your modem speed. For example:  
4. Baud Rate  
Modem Speed  
2400 bps  
Baud Rate selection  
9600 bps  
9600 bps  
38,400 bps  
57,600 bps  
115,200 bps  
14,400 bps  
28,800 bps  
5. Flow Control  
Set the flow control between the computer and the modem can prevent data over run during transmission. There are two common ways of setting the flow control.  
Software Flow control or XON/XOFF  
Hardware Flow Control or CTS/RTS  
Most of the data communication software has the option for setting the above parameters. In order to let the modem communicate flawlessly, these settings must be identical between the two modems except  
Baud Rate and Flow Control.  
- 13 -  
 
OPERATING MODE  
OPERATING MODE  
OPERATING MODE  
The Fax/Data Modem operating modes, which is selectable by the \Nn command, these commands allow the DCE (modem) to communicate with remote modems that may or may not support error  
correction and data compression. The operating modes are Normal, Direct, Reliable link, Auto-reliable, V.42 Reliable Mode, and MNP Reliable Mode. Speed buffering, which is used for all operating modes  
except \N1, allows the DTE(computer)-to-modem data rate to be different from the modem-to-modem data rate. This is accomplished by using transmitting and receiving buffers in the modem as speed buffer.  
Thus, the DTE-to-modem data rate can be set for 38,400 bps when the modem-to-modem data rate is 9,600 bps, without causing any data errors. In all data modes except direct mode (\N1), the DTE-to-  
modem data rate can be set for any valid speed between 300 bps and 57,600 bps. (In direct mode, the DTE-to-modem data rate can only be set to 300, 1200, 2400, 4800, 7200, 9600, 12000, and 14400  
bps.)  
Each operating mode is explained as the following:  
Normal Mode  
%
No error correction/data compression, but speed  
buffering is supported.  
Direct Mode  
%
%
No error correction/data compression and speed buffering.  
Reliable Mode  
V.42, V.42 bis or MNP 2-5 only connection. The modem hangs up if a V.42/V.42 bis/MNP 2-5  
connection cannot be established.  
Auto-Reliable Mode  
V.42 Reliable Mode  
MNP Reliable Mode  
%
-
V.42/V.42 bis with fall back to MNP 2-5 or normal mode.  
V.42/V.42 bis connection only. The modem hangs up if an V.42/V.42 bis connection cannot be established.  
MNP 2-5 connection only. The modem hangs up if an MNP connection cannot be established.  
%
If you have difficulty connecting to a remote modem, try using the Normal mode or Direct mode.  
The table below shows the \Nn and other commands needed to setup a desired operating mode.  
Data/Fax Modem Speed  
All of these commands have a prefix AT&F  
Operating Mode  
2400  
9600  
14.4/14.4  
14.4/14.4CL  
28.8/14. 4  
- 14 -  
 
DATA COMMUNICATION  
Normal  
\N0  
\N1  
\N2  
\N3  
\N0  
\N1  
\N2  
\N3  
\N0  
\N1  
\N2  
\N3  
\N0  
\N1  
\N4  
\N3  
\N0  
\N1  
\N2  
Direct  
Reliable  
Auto-Reliable  
\N3 with  
MNP10  
V.42 Only  
MNP Only  
\N4  
\N5  
\N4  
\N5  
\N4  
\N5  
\N4 -J0 AH0  
\N4  
\N5  
\N2  
File Transferring  
To transfer files between two computers user will need to choose a file transfer protocol once the two modems are connected. There are many different types of file transfer protocol. Each has  
advantage and disadvantage on their own. The following are some guide - line in file transferring:  
C
C
After log in to a remote computer check, the protocol its using. Make sure your protocol matches the remote computers. Here are, some names of the popular protocols: COMPUSERVE B,  
Kermit, XMODEM, YMODEM, ZMODEM.  
The remote computer will wait for a user to start the file transfer sequence. The user must tell the communication software to start sending or receiving the selected files.  
Remote Access  
The best source of the information for setting up a remote access software is its User=s manual. A user needs to fill in which type of modem to use (consult the modem choice section) and the flow  
control selection.  
If you are having some difficulty connecting to a remote computer, change the init string for the modem to use Normal or Direct Mode. Some of the remote access programs have an error correction  
and/or data compression built-in to the software. Disabling Fax/Data Modem=s errorcorrection and/or data compression may be required for this operation.  
CELLULAR OPERATION  
For the >Cellular ready= modem owner, you will need to obtain a proper cellular interface cable kit that matches the make and model your cellular phone.(see the Notice: below)  
Please follow these suggestions:  
C
C
C
Verify if the modem is installed and recoqnized by the system. Using PCMCIA sockets driver utility such as Cardinfo or PCMWIN etc.  
Check the modem operation with the land line using any communication program for DOS or Windows.  
You need to run an installation program to activate the cellular function included with the cellular interface kit. For more details consult the User=s manual and the README file in the driver  
diskette.  
For the >None - Cellular ready= Fax/Data Modem, you will need a cellular interface adapter. This adapter provide Dial Tone for the modem and cellular cable kit matching your cellular phone make and model.  
Operating consideration:  
- 15 -  
 
FAX OPERATION  
C
C
Because of the cellular phone environment, modem=s connection speed may be slower than the actual rated. (9600 bps is the fastest)  
The MNP 10 protocol (cellular enhancement) is included with the 28,800 and all the cellular-ready modem.  
Notice: For the Cellular Ready Modem only  
This product contains inactivated SPECTRUM CONNECTED  
cellular data  
communication technology which can be activated for data communication over a cellular  
net work when a license is obtained from SPECTRUM and the product is combined with  
an appropriate cellular telephone driver and corresponding cable compatible with popular  
brands of cellular telephones. To obtain a license and to determine the availability of an  
appropriate driver and cable for cellular telephone, contact Spectrum Information  
Technologies, Inc. by calling 800-233-2119  
This product is licensed under one or more of the following United Stats patents:  
RE 34 034; 4,9972,457; 5,127,041; and 5,249,218 of Spectrum Information  
Technologies, Inc. Other patent pending  
FAX OPERATION  
The Fax/Data Modems support Group III Class 1(EIA/TIA 578) or Class 2 commands, which are part of the AT command set. The fax software included with your modem will automatically handle the fax  
operation for you. Please refer to the manual of your fax software on how to send and receive faxes from your computer with the Fax/Data modems. If you are using fax software other than the one included,  
the installation of the software may ask you to specify the type of fax modem. You may select either Class 1 or Class 2 type fax. Consult the list below for your specific modem speed.  
Your modem speed Select Fax Class  
2400, 9600, 14,400  
14,400CL  
Class 1, Class 2 or Hayes V series  
Class 1 or Hayes Optima 14,400 + Fax  
Class 1, Class 2 or Hayes Optima  
CTS/RTS or Hardware is recommended  
(14,400 use Hayes Optima 14,400 + Fax)  
28,800  
Flow Control  
The Fax/Data Modems with the UART 16550 ( 2400, 9600 and 14,400/14,400) emulation may have problems sending faxes under the Microsoft Windows. The following lines additions and/or changes in the  
SYSTEM.INI file will correct the problem.  
SYSTEM.INI  
- 16 -  
 
;changes in this section of file  
[386 Enh]  
COMxFIFO=2  
COMxTXFIFO=1  
COMxBOOSTTIME=30  
COMxPROTOCOL=XOFF  
COMxBUFFER=4096  
COMxAUTOASSIGN=2  
COMxTXSIZE=16  
COMxRXSIZE=8  
The "x" is the number of the COM port. You must be sure to be running in the enhanced mode. You can force windows to go into enhanced mode by starting Windows with the command win /3.  
The above entries work with:  
1) UART 16550 emulation  
2) normal version of COMM.DRV  
Otherwise the entries will be ignored.  
- 17 -  
 
DIAGNOSTIC  
DIAGNOSTIC FUNCTION  
Setting up for the diagnostic operation: Start the data communication software, then enter the >Terminal Mode= or >Connect Mode=. Set the COM port to match the number use by the modem type >at= then press  
ENTER key to check the modem installation.  
The Fax/Data Modem supports diagnostic functions defined by ITU (CCITT) V.54 to assist identifying problems of the modem. Basically, these functions loop signals on the local and remote modems to  
simulate data communication activities.  
These diagnostic functions must be performed under asynchronous operation in non-error-correction mode(normal or direct mode). In command mode, use AT\N1 to enter direct asynchronous mode. To stop  
any diagnostic functions in progress, use the escape (+++) sequence to go to command mode, and type AT&T0 .  
Local Analog Loopback  
This test will loop data from computer to the modem. Use AT&T1 to start the test. CONNECT XXXXX message will be displayed upon the start of the test. After the connection, characters typed on  
the computer will be transmitted to the modem and then return to the computer to be displayed on the screen.  
Local Analog Loopback with Self-test  
Use AT&T8 to initialize this test. The modem will generate a test pattern and looped back and checked by the modem itself. The testing duration is set by the contents of S18. Upon the termination  
of the test, it returns the number of detected errors to the computer. Register S16 bit 6 will be set when the test is in progress.  
Remote Digital Loopback  
Use AT&T6 to initialize this test. The test is to check the connection fault between a local modem and a remote modem. Data is routed from local computer to the local modem, then through the  
phone connection to a remote modem. The remote modem then retransmit the data through the same connection back to the local modem, then to the local computer. Before the test, you must establish a  
connection with a remote modem. If no connection is made, ERROR message will be returned. The CONNECT XXXX message will be displayed upon the start of the test. After the connection, all characters  
you typed on computer will be remote loopbacked and redisplayed on your screen.  
Remote Digital Loopback with Self-test  
Use AT&T7 to initiate the test, and a test pattern will be looped back and checked by the modem. If no connection is made before the start of the test, ERROR message will be returned. The test  
duration is determined by the contents of S18. Upon the termination of the test, it returns the number of detected errors to the computer. Register S16 bit 5 will be set when the test is in progress.  
Local Digital Loopback  
Before the start of the test, a connection to a remote modem must be established. If no connection, ERROR message will be displayed. Use AT&T3 to start the test. After the start of the test,  
characters typed on the remote computer will be routed from the remote modem to the local modem through the connection. The local modem will then return the data to the remote modem, and then  
redisplayed on the screen of the remote computer. Register S16 bit 4 will be set when the test is in progress.  
- 18 -  
 
TROUBLESHOOTING  
TROUBLESHOOTING  
This section lists the common problems and possible causes and/or solutions. You may find the answer to your problem here.  
Problem  
Solution  
NO DIAL TONE  
!
!
!
Check the phone connection on both sides of the cable.  
Ensure the telephone is an Analog line not Digital line.  
Check the telephone line by connecting a standard telephone,  
listen to the normal house hold dial tone.  
!
Bypass Dial tone detection, add >X3' to the init string.  
Cannot hear  
modem speaker  
!
!
Check the computer volume setting.  
In Terminal Mode send >ATL3M1' command to the modem, this  
will enable modem sound until its connection to a remote  
modem with the highest volume.  
The selected COM  
port is either not  
supported or is  
being used by  
!
!
Disable Auto-receive in the FAX program.  
Check the COM Port I/O address and IRQ setting.  
Click on: Main Group => Control Panel => Ports => COM x  
(x=com port 1-4)  
other devices.  
!
!
Ensure that only one program is using the modem.  
Cannot type >AT=  
in terminal mode.  
Check the IRQ setting in your application program, make sure  
that it matches the setting from the device driver.  
!
Some program may not support IRQ higher than 7.  
Failed to connect  
!
!
Check your modem choice.  
Try adding the \N1 as the last command to the init string.  
Modem doesn=t fit  
!
!
Make sure the computer has Type II or Type III slot.  
Check the User=s manual for the PC Card=s slot location.  
Can=t Send or  
!
Ensure you select the right fax Class for the modem  
Receive fax  
or try selecting fax Class 1 with CTS/RTS (Hardware) flow  
control.  
Unreadable  
character on the  
screen  
!
Check and make sure the communication parameters match the  
remote location, i.g., Data Bit, Parity, Stop Bit  
Cannot find  
modem  
!
!
Use PC Card driver utility >Cardinfo= or >PCMinfo= to make sure  
modem is configured.  
Using MSD to verify that you have an additional COM port after  
- 19 -  
 
TROUBLESHOOTING  
modem is inserted.  
!
Redo the installation procedures.  
APPENDIX A  
What is PC Card (PCMCIA) device driver?  
A PC Card device driver contains several components: Socket services, Card services, Resource Initialization Utility and Card Installation Utility. The remaining of this section will explain the four components  
and list the names of the device driver for some major PC Card software vendors.  
Socket Services provides the interface between a system*s BIOS and the host controller chips (such as the Intel 82365SL PCIC and the DataBook TCIC-2/N). Socket Services includes functions such as  
configuring a socket for an I/O or memory interface and controlling socket power voltages. The Socket Services driver operates the host controller chip of your computer.  
Card Services provides the interface between the PC Card card and the Sockets Service driver. To make sure Card Services operate flawlessly regardless of the system, some PC Card device driver provide  
their own resource initialization utility, which will check all of the I/O ports, IRQs, and memory addresses used by the computer and report that information to Card Services.  
The Card Installation Utility detects the insertion and removal of a PC Card, and determines the card type upon insertion, then the card and socket will be configured properly.  
These components are loaded into the system during boot-up via the statements in the C:\CONFIG.SYS file. Along with the four components you may find other types of device drivers for various types of PC  
Card like SRAM card, FLASH memory card, and ATA/IDE hard drive card.  
- 20 -  
 
TROUBLESHOOTING  
The name of device drivers for the major PC Card software vendors are listed below:  
Software/Device  
Driver  
SystemSoft  
CardSoft  
Phoenix  
Databook  
Cardtalk  
Socket Services  
SS365SL.EX  
E,  
PCMSS.  
EXE  
SNOTEP  
V2.SYS  
SS365LP.EX  
E,  
SSCIRRUS.  
EXE,  
SSDBOOK.E  
XE,  
SVADEM.EX  
E,  
SSVLSI.EXE  
CS.EXE  
Card Services  
PCMCS.  
EXE  
CTALKCS  
.EXE  
Resource  
Initialization  
Utility  
CSALLOC.E  
XE  
PCMRM  
AN.SYS  
IDE/ATA Driver  
S_IDE.EXE  
or  
PCMATA  
.SYS  
ATADRV.EX  
E
SRAM Card  
Driver  
SRAMDRV.E  
XE or  
MTSRAM.EX  
E
Flash Card  
Support  
MTAA.EXE,  
MTAB.EXE,  
MTI1,EXE  
MTI2P.EXE  
Memory Card  
Driver  
SCARD29.E  
XE or  
MEMDRV.E  
XE  
Card Installation  
Utility  
CIC.EXE or  
PCMSC  
D.EXE  
CARDTAL  
K.SYS  
CARDID.EX  
E
- 21 -  
 
Card Services  
CS_APM.EX  
E
Power  
Management  
Basic >AT= command for 28,800 Modem  
Command  
Function  
A/  
Re-execute command.  
A
Go off-hook and attempt to answer a call.  
Select V.22 connection at 1200 bps.  
Select Bell 212A connection at 1200 bps.  
Return OK message.  
B0  
B1  
C1  
Dn  
E0  
E1  
H0  
H1  
I0  
Dial modifier.  
Turn off command echo.  
Turn on command echo.  
Initiate a hang-up sequence.  
If on-hook, go off-hook and enter command mode.  
Report product code.  
I1  
Report pre-computed checksum.  
Report OK.  
I2  
I3  
Report firmware revision, model, and interface type.  
Report response programmed by an OEM.  
Report the country code parameter.  
Report modem data pump model and code revision.  
Reports the DAA code (W-class models only).  
Set low speaker volume.  
I4  
I5  
I6  
I7  
L0  
L1  
L2  
L3  
M0  
M1  
M2  
M3  
N0  
Set low speaker volume.  
Set medium speaker volume.  
Set high speaker volume.  
Turn speaker off.  
Turn speaker on during handshaking and turn speaker off while receiving carrier.  
Turn speaker on during handshaking and while receiving carrier.  
Turn speaker off during dialing and receiving carrier and turn speaker on during answering.  
Turn off automode detection.  
- 22 -  
 
APPENDIX A  
N1  
O0  
O1  
P
Turn on automode detection.  
Go on-line.  
Go on-line and initiate a retrain sequence.  
Force pulse dialing.  
Q0  
Q1  
Sn  
Sn?  
=v  
Allow result codes to DTE.  
Inhibit result codes to DTE.  
Select S-Register as default.  
Return the value of S-Register n.  
Set default S-Register to value v.  
Return the value of default S-Register.  
Force DTMF dialing.  
?
T
V0  
V1  
W0  
W1  
W2  
X0  
X1  
Report short form (terse) result codes.  
Report long form (verbose) result codes.  
Report DTE speed in EC mode.  
Report line speed, EC protocol and DTE speed.  
Report DCE speed in EC mode.  
Report basic call progress result codes, i.e., OK, CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO ANSWER and ERROR.  
Report basic call progress result codes and connections speeds (OK, CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO ANSWER,  
CONNECT XXXX, and ERROR.  
X2  
Report basic call progress result codes and connections speeds, i.e., OK, CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO  
ANSWER, CONNECT XXXX, and ERROR.  
X3  
Report basic call progress result codes and connection rate, i.e., OK, CONNECT, RING, NO CARRIER, NO ANSWER, CONNECT XXXX, BUSY, and ERROR.  
X4  
Report all call progress result codes and connection rate, i.e., OK, CONNECT, RING, NO CARRIER, NO ANSWER, CONNECT XXXX, BUSY, NO DIAL TONE and ERROR.  
Y0  
Disable long space disconnect before on-hook.  
Enable long space disconnect before on-hook.  
Restore stored profile 0 after warm reset.  
Restore stored profile 1 after warm reset.  
Force RLSD active regardless of the carrier state.  
Allow RLSD to follow the carrier state.  
Y1  
Z0  
Z1  
&C0  
&C1  
&D0  
Interpret DTR ON-to-OFF transition per &Qn:  
&Q0, &Q5, &Q6  
&Q1, &Q4  
The modem ignors DTR.  
The modem hangs up.  
The modem hangs up.  
&Q2, &Q3  
&D1  
Interpret DTR ON-to-OFF transition per &Qn:  
&Q0, &Q1, &Q4,.  
- 23 -  
 
APPENDIX A  
&Q5, &Q6  
&Q2, &Q3  
Asynchronous escape.  
The modem hangs up.  
&D2  
&D3  
Interpret DTR ON-to-OFF transition per &Qn:  
&Q0 thru &Q6 The modem hangs up.  
Interpret DTR ON-to-OFF transition per &Qn:.  
&Q0, &Q1, &Q4,.  
&Q5, &Q6  
&Q2, &Q3  
The modem performs soft reset.  
The modem hangs up.  
&F0  
&F1  
&G0  
&G1  
&G2  
&J0  
Restore factory configuration 0.  
Restore factory configuration1.  
Disable guard tone.  
Disable guard tone.  
Enable 1800 Hz guard tone.  
Set S-Register response only for compatibility.  
Set S-Register response only for compatibility.  
Disable DTE/DCE flow control.  
&J1  
&K0  
&K3  
&K4  
&K5  
&K6  
&L0  
&L1  
&M0  
&M1  
&M2  
&M3  
&P0  
&P1  
&P2  
&P3  
&Q0  
&Q1  
&Q2  
&Q3  
&Q4  
Enable RTS/CTS DTE/DCE flow control.  
Enable XON/XOFF DTE/DCE flow control.  
Enable transparent XON/XOFF flow control.  
Enable both RTS/CTS and XON/XOFF flow control.  
Select dial up line operation.  
Select leased line operation.  
Select direct asynchronous mode.  
Select sync connect with async off-line command mode.*  
Select sync connect with async off-line command mode and enable DTR dialing of directory zero.*  
Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch.*  
Set 10 pps pulse dial with 39%/61% make/break.  
Set 10 pps pulse dial with 33%/67% make/break.  
Set 20 pps pulse dial with 39%/61% make/break.  
Set 20 pps pulse dial with 33%/67% make/break.  
Select direct asynchronous mode.  
Select sync connect with async off-line command mode.*  
Select sync connect with async off-line command mode and enable DTR dialing of directory zero.*  
Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch.*  
Select Hayes AutoSync mode.  
- 24 -  
 
APPENDIX A  
&Q5  
&Q6  
&R0  
&R1  
&S0  
&S1  
&T0  
&T1  
&T2  
&T3  
&T4  
&T5  
&T6  
&T7  
&T8  
&V  
Modem negotiates an error corrected link.  
Select asynchronous operation in normal mode.  
CTS tracks RTS (async) or acts per V.25 (sync).  
CTS is always active.  
DSR is always active.  
DSR acts per V.25.  
Terminate any test in progress.  
Initiate local analog loopback.  
Returns ERROR result code.  
Initiate local digital loopback.  
Allow remote digital loopback.  
Disallow remote digital loopback request.  
Request an RDL without self-test.  
Request an RDL with self-test.  
Initiate local analog loop with self-test.  
Display current configurations.  
&W0  
&W1  
&X0  
&X1  
&X2  
&Y0  
&Y1  
&Zn=x  
%E0  
%E1  
%E2  
%L  
Store the active profile in NVRAM profile 0.  
Store the active profile in NVRAM profile 1.  
Select internal timing for the transmit clock.  
Select external timing for the transmit clock.  
Select slave receive timing for the transmit clock.  
Recall stored profile 0 upon power up.  
Recall stored profile 1 upon power up.  
Store dial string x (to 35) to location n (0 to 3).  
Disable line quality monitor and auto retrain.  
Enable line quality monitor and auto retrain.  
Enable line quality monitor and fallback/fall forward.  
Return received line signal level.  
%Q  
Report the line signal quality.  
%TTn  
\G0  
PTT certification test signals.  
Disable modem to modem flow control.  
Enable modem to modem flow control.  
Controls break handling during three states:  
When modem receives a break from the DTE:  
Enter on-line command mode, no break sent to the remote modem.  
Clear buffers and send break to remote modem.  
\G1  
\Kn  
\K0,2,4  
\K1  
- 25 -  
 
APPENDIX A  
\K3  
\K5  
Send break to remote modem immediately.  
Send break to remote modem in sequence with transmitted data. When modem receives \B in on-line command state:  
Clear buffers and send break to remote modem.  
\K0,1  
\K2,3  
Send break to remote modem immediately.  
\K4,5  
\K0,1  
\K2,3  
\K4,5  
\N0  
Send break to remote modem in sequence with transmitted data.When modem receives break from the remote modem:  
Clear data buffers and send break to DTE.  
Send a break immediately to DTE.  
Send a break with received data to the DTE.  
Select normal speed buffered mode.  
Select direct mode.  
\N1  
\N2  
Select reliable link mode.  
\N3  
Select auto reliable mode.  
\N4  
Force LAPM mode.  
\N5  
Force MNP mode.  
+MS  
Select modulation  
ECC COMANDS  
%C0  
%C1  
%C2  
%C3  
Disable data compression.  
Enable MNP 5 data compression.  
Enable V.42 bis data compression.  
Enable both V.42 bis and MNP 5 compression.  
\A0  
\A1  
\A2  
\A3  
\Bn  
Set maximum block size in MNP to 64.  
Set maximum block size in MNP to 128.  
Set maximum block size in MNP to 192.  
Set maximum block size in MNP to 256.  
Send break of n x 100 ms.  
MNP 10 COMMANDS  
)M0  
)M1  
Disable MNP 10 link negotiation power adjustment.  
Enable MNP 10 link negotiation power adjustment.  
*H0  
*H1  
*H2  
Select MNP 10 link negotiation at highest rate.  
Select MNP 10 link negotiation at 1200 bps.  
Select MNP 10 link negotiation at 4800 bps.  
- 26 -  
 
APPENDIX A  
-K0  
Disable MNP 10 extended services.  
-K1  
Enable MNP 10 extended services.  
-K2  
-Q0  
-Q1  
@M0  
Enable MNP 10 extended services detection only.  
Disable MNP 10 fallback to 2400 bps (V.22 bis)/1200 bps (V.22).  
Enable MNP 10 fallback to 2400 bps (V.22 bis)/1200 bps (V.22).  
Select initial transmit level of -26 dBm.  
@M1  
Select initial transmit level of -30 dBm.  
@M2  
Select initial transmit level of -10 dBm.  
@M3 - @M10  
Select initial transmit level of -10 dBm.  
@M11  
Select initial transmit level of -11 dBm.  
@M12  
-Select initial transmit level of -12 dBm.  
.
.
.
@M30  
@M31  
Select initial transmit level of -30 dBm.  
Select initial transmit level of -31 dBm.  
:E0  
:E1  
Disable the compromise equalizer.  
Enable the compromise equalizer.  
CALLER ID COMMANDS  
#CID=0  
#CID=1  
#CID=2  
Disable Caller ID.  
Enable Caller ID with formatted presentation.  
Enable Caller ID with unformatted presentation.  
- 27 -  
 
APPENDIX A  
CELLULAR COMMANDS  
^C2  
^I  
^T6  
Download cellular phone driver.  
Identify cellular phone driver.  
Indicate status of cellular phone.  
- 28 -  
 
APPENDIX A  
Basic >AT= command for 1414 CL  
Command  
Default  
Function  
A/  
A
none  
none  
Repeat last command  
Answer  
B0  
B1  
C0  
C1  
D
Select ITU connection  
Select Bell connectionor  
Disable Carrier control  
Enable Carrier control  
Dial command  
*
*
none  
E0  
E1  
F0  
F1  
H0  
H1  
I0  
Disable Command echo  
Enable Command echo  
Disable On-line echo  
Enable On-line echo  
Start Hang-up sequence  
*
*
*
If On-hook, go off-hook and enter command mode  
Report ID code  
*
I1  
Report checksum  
I2  
Report OK  
I3  
I4  
Report firmmware revision,model  
Report Manufacturer ID code  
SRAM buffer control  
Set low speaker volume control  
Set low speaker volume control  
Set medium speaker volume control  
Set high speaker volume control  
Turn speaker off  
Turn speaker on during handshaking and turn speaker off while receiving carrier.  
Turn speaker on during handshaking and while receiving carrier.  
Turn speaker off during dailing, receiving carrier and turn speaker on during answering.  
Disable connection data rate control  
Enable connection data rate control  
Go on line  
Select pulse dialing  
Enable result code display  
Disable result code display  
Select an S-register  
Write to an S-register  
Read from an S-register  
K0  
L0  
L1  
L2  
L3  
M0  
M1  
M2  
M3  
N0  
N1  
On  
P
Q0  
Q1  
Sn  
Sn=x  
Sn?  
?
*
*
*
*
0
none  
*
none  
none  
none  
none  
*
Read last accessed S-register  
Select DTMF dialing  
T
V0  
V1  
X0  
X1  
X2  
X3  
X4  
Report result code short form  
Report result code long (verbose) form  
Report basic call progress i.e., OK, CONNECT, RING, NO CARRIER  
Report basic call progress and connection speed i.e., OK, CONNECT, RING, NO CARRIER CONNECT XXXX and ERROR (no Dial tone detection)  
Report basic call progress and connection rate i.e., OK, CONNECT, RING, NO CARRIER CONNECT XXXX and ERROR (no Dial tone detection)  
Report basic call progress and connection rate i.e., OK, CONNECT, RING, NO CARRIER CONNECT XXXX NO ANSWER and ERROR (no Dial tone detection)  
Report basic call progress and connection rate i.e., OK, CONNECT, RING, NO CARRIER, RING CONNECT XXXX NO ANSWER, BUSY NO DIAL TONE and  
ERROR  
*
- 29 -  
 
APPENDIX A  
Y0  
Y1  
Z1  
*
Disable long space disconnect  
Enable long space disconnect Z0  
Recall stored profile 1  
*
Recall stored profile 0  
&C0  
&C1  
&D0  
Force DCD active  
Allow DCD to follow carrier state  
In a sync hronous mod e (&Q0), the mod e m ig nore s DTR.  
*
0
1
The mod e m switc he s from d a ta mod e to c omma nd mod e whe n a n on-to-off tra nsition of DTR oc c urs.  
2*  
An on-to-off tra nsition of DTR c a use s the mod e m to g o on-hook (ha ng -up ) a nd d isa b le a uto-a nswe r mod e . Auto-a nswe r mod e (S0 is not e q ua l to ze ro)  
is e na b le d whe n DTR is turne d on. *  
3
An on-to-off tra nsition of DTR re -initia lize s the mod e m. The re -initia lize p roc e d ure p e rforms a p owe r-up re se t, e xc e p t tha t the UART re g iste rs a re not re -  
c onfig ure d . DTR option  
&F  
&G  
none  
0*  
1
Load factory defaults  
Guard tone disabled  
550-Hz g ua rd tone e na b le d .  
2
1800-Hz g ua rd tone e na b le d .  
&J  
0
Auxiliary relay is never operate  
1
0*  
1
0*  
1
A lead is connected to the A1 lead the modem is off-hook  
Ma ke = 39%; Bre a k = 61% for use in the Unite d Sta te s. *  
Ma ke = 33%; Bre a k = 67% for use in the Unite d King d om a nd Hong Kong .  
Force DSR alway active  
&Pn  
&Sn  
&Tn  
DSR c irc uit is on d uring ha nd sha king , off in te st or id le mod e s. DSR is on whe n c a rrie r is lost.  
0*  
Te rmina te s te st in p rog re ss  
1
Loc a l a na log loop b a c k  
3
Loc a l d ig ita l loop b a c k  
4
5
6
Gra nts RDL re q ue st from re mote mod e m  
De nie s RDL re q ue st from re mote mod e m  
Re mote d ig ita l loop b a c k  
7
8
Re mote d ig ita l loop b a c k with se lf-te st  
Loc a l a na log loop b a c k with se lf-te st  
&Un  
&Vn  
0*  
1
0*  
1
Ena b le d (Tre llis mod ula tion with QAM mod ula tion a s a fa llb a c k)  
Disa b le d (QAM mod ula tion only)  
View active and stored configuration 0  
View active and stored configuration 1  
AT&V1  
Ac tive Profile :  
+ FCLASS= 0 # VCL= 0 # VLN= 25  
B1 E1 L2 M1 N1 P Q0 V1 X4 Y0 &C1 &D2 &G0 &J0 &P0 &Q0 &S0 &Y0 -C0 %E1 %G0  
\A3 \C0 \G0 \J0 \K5 \N3 \T00 \V2 \X0 %A013 %C1 -J1 "H3 "O016  
S00:000 S01:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07: 060 S08:002  
S09:006 S10:014 S11:095 S12:050 S14:170 S16:000 S18:000 S21:048 S22:118  
S23:021 S25:005 S26:001 S27:064 S30:010 S37:000 S90:000 S108:002 S109:062  
Store d Profile 1:  
B1 E1 L2 M1 N1 P Q0 V1 X4 Y0 &C1 &D2 &G0 &J0 &P0 &Q0 &R0 &S0 &X0  
\A3 \C0 \G0 \J0 \K5 \N3 \T00 \V2 \X0 %A013 %C1 -J1 "H3 "O016  
S00:000 S06:002 S07: 060 S08:002 S09:006 S10:014 S11:095 S12:050 S14:170  
S16:000 S18:000 S21:048 S22:118 S23:021 S25:005 S26:001 S27:064 S30:010  
- 30 -  
 
APPENDIX A  
S37:000 S90:000 S108:002 S109:062  
Te le p hone Numb e rs:  
&Z0 12345  
&Z1 T4444444  
&Z2 T12345  
&Z3 T 1 (123) 456-7890  
&W  
0
1
Store a c tive p rofile in use r p rofile 0  
Store in active profile use r p rofile 1  
Select stored profile 0 on power up  
Select stored profile 1 on power up  
Store telephone number  
&Y  
0*  
1
none  
&Zn=x  
To d ia l the store d te le p hone , use the  
ATDS= n c omma nd .  
x = 0, 9, A, B, C, D, # , *, T, P, R, W, @, ,,!,;  
n = 0-3  
%E  
0
Disable Auto-retrain ( V.32 and V.32bis Only)  
Enable Auto-retrain  
Disable Auto Fallforward/fallback Rate  
Enable Auto Fallforward/fallback Rate  
Line signal quality  
Ra ng e : 0-255  
0 - 7 No Re tra in  
Diable data modem calling tone  
Enable data modem calling tone  
1 *  
0 *  
1
%G0  
Renegotiation  
Renegotiation  
%Q  
-Cn  
*
none  
8 - 255 Mod e m p e rforms a Re tra in (i.e ., if c onfig ure d for %E1)  
0*  
1
Value saved in NVRAM.  
V.42, MNP 'AT' Commands  
Command  
Default  
Function  
%A  
%C  
13  
0
Set auto-reliable fallback character  
No data compression  
1*  
0
1
MNP 5 data compression control  
\A  
MNP block size Ma ximum 64 c ha ra c te rs  
MNP block size Ma ximum 128 c ha ra c te rs  
MNP block size Ma ximum 192 c ha ra c te rs  
MNP block size Ma ximum 256 c ha ra c te rs  
Transmit break (n=0-9 Break lenght in 100 msec)  
Does not buffer data  
2
3*  
none  
0*  
1
\Bn  
\C  
Buffe rs d a ta for four se c ond s until 200 c ha ra c te rs ha ve b e e n b uffe re d or SYN c ha ra c te r is d e te c te d , the n switc he s to re lia b le mod e . If the b uffe r fills,  
d a ta is p a sse d to the se ria l p ort.  
2
Doe s not b uffe r d a ta . Switc he s to norma l mod e up on re c e ip t of a uto-re lia b le fa llb a c k c ha ra c te r a nd p a sse s it to se ria l p ort. This fe a ture is use d to  
a llow non-V.42 mod e ms to c onne c t imme d ia te ly to a V.42 mod e m without d a ta loss. Set auto-reliable buffer  
\G  
0 *  
1
0 *  
Disable modem port flow control  
Set port flow control to XON/XOFF  
Disable Bps rate adjusting  
\Jn  
- 31 -  
 
APPENDIX A  
1
5
Enable Bps rate adjusting  
Set break control  
\Kn  
In Connect State, if reliable mode then transmit break to remote:  
n = 0,2,4  
n = 1  
Enter command state, but do not send a break.  
Destructive/expedited  
n = 3  
n = 5  
Non-destructive/expedited  
Non-destructive/non-expedited  
In Command State, if reliable mode then transmit break to remote:  
n = 0,1  
n = 2,3  
n = 4,5  
Destructive/expedited  
Non-destructive/expedited  
Non-destructive/non-expedited  
In Connect State, if direct mode then receive break at serial port:  
n = 0,2,4  
n = 1,3,5  
Immediately send break and enter command state.  
Immediately send break through  
In Connect State, receive break at modem port, send to serial port:  
n = 0,1  
n = 2,3  
n = 4,5  
Destructive/expedited  
Non-destructive/expedited  
Non-destructive/non-expedited  
\Nn  
Se t Op e ra ting Mod e : De te rmine s the typ e of  
c onne c tion a tte mp te d b y the mod e m.  
n = 0 Norma l Mod e -No d a ta c omp re ssion or e rror c orre c tion, b ut use s sp e e d b uffe ring .  
n = 1 Dire c t Mod e - No d a ta c omp re ssion, e rror c orre c tion, or sp e e d b uffe ring .  
n = 2 MNP Re lia b le Mod e -The mod e m a tte mp ts to ne g otia te a n MNP e rror-c orre c tion 're lia b le ' link, ha ng ing up if it fa ils.  
n = 3 V.42 Auto-re lia b le Mod e * If V.42 d e te c tion is e na b le d (-Jn), a LAPM or MNP link c a n b e d e te c te d a nd ne g otia te d , othe rwise only LAPM will b e  
a tte mp te d . If c onfig ure d for -J0 a nd a p rotoc ol c onne c tion is not ma d e , the mod e m will ha ng up . If c onfig ure d for -J1 a nd a p rotoc ol  
c onne c tion is not ma d e , the mod e m will fa ll b a c k to sp e e d b uffe ring mod e .  
n = 4 V.42 Re lia b le - The mod e m a tte mp ts to ne g otia te LAPM e rror c orre c tion, ha ng ing up if it fa ils.  
NOTE: 300 b p s d oe s not sup p ort sync hronous op e ra tion. The mod e will a utoma tic a lly fa ll b a c k to MNP a sync hronous op e ra tion.  
\O  
\Qn  
none  
0
Originate reliable link  
Disables flow control  
1
2
3*  
0*  
XON/XOFF software flow control  
Unidirectional hardware flow control  
Bidirectional hardware flow control  
Disable inactivity timer  
\T  
0-90 Lenth in minutes  
\U  
\Vn  
none  
0
1
Accept reliable link  
Enables codes defined by ATV command  
Enables modified MNP codes  
2*  
Enables extended V.42 codes  
\X  
0*  
1
none  
none  
0
Processes flow control characters *  
Processes flow control characters and passes them through to the local or remote so they can process the characters.  
Switch to reliable mode  
Switch to normal mode  
Disable the V.42 detect phase  
\Y  
\Z  
-Jn  
(\N3,\N4 operating mode)  
1*  
Enable the V.42 detect phase  
- 32 -  
 
APPENDIX A  
(\N3,\N4 operating mode)  
"Hn  
0
Disa b le s V.42 b is  
1
2
3*  
16  
Ena b le s V.42 b is only whe n tra nsmitting d a ta  
Ena b le s V.42 b is only whe n re c e iving d a ta  
Ena b le s V.42 b is for b oth tra nsmitting a nd re c e iving d a ta  
V.42 bis string length (range 6-250 Number of charecters)  
"On  
*
Value saved in NVRAM.  
Dial Modifiers  
Command  
Function  
0 to 9  
Dialing digits  
A,B,C,  
Tone dial characters  
D, *, #  
P
Pulse dial  
R
S=n  
T
Reverse originate mode  
Dial NVRAM telephone number  
Tone dial  
W
,
Wait for dial tone  
Pause  
!
Flash hook  
@
;
- ( )  
Wait for quiet answer  
Return to idle state  
Ignored by modem  
- 33 -  
 
APPENDIX A  
Basic AT command for 2400, 9600 and 14,400 modem.  
Command  
Function  
A/  
Re-execute command.  
A
Go off-hook and attempt to answer a call.  
Select V.22 connection at 1200 bps.  
Select Bell 212A connection at 1200 bps.  
Return OK message.  
Dial modifier.  
Turn off command echo.  
Turn on command echo.  
Select auto-detect mode (equivalent to N1).  
Select V.21 or Bell 103.  
Reserved.  
Select V.23 line modulation.  
Select V.22 or Bell 212A 1200 bps line speed.  
Select V.22 bis line modulation.  
Select V.32 bis or V.32 4800 line modulation.  
Select V.32 bis 7200 line modulation.  
Select V.32 bis or V.32 9600 line modulation.  
Select V.32 bis 12000 line modulation.  
Select V.32 bis 14400 line modulation.  
Initiate a hang-up sequence.  
B0  
B1  
C1  
Dn  
E0  
E1  
F0  
F1  
F2  
F3  
F4  
F5  
F6  
F7  
F8  
F9  
F10  
H0  
H1  
I0  
If on-hook, go off-hook and enter command mode.  
Report product code.  
I1  
I2  
I3  
I4  
I5  
I6  
L0  
L1  
L2  
L3  
M0  
M1  
M2  
M3  
N0  
N1  
O0  
O1  
P
Report pre-computed checksum from ROM.  
Compute checksum and report status.  
Report firmware revision, model, and interface type.  
Report response programmed by an OEM.  
Report the country code number.  
Report modem data pump model.  
Set low speaker volume.  
Set low speaker volume.  
Set medium speaker volume.  
Set high speaker volume.  
Turn speaker off.  
Turn speaker on during handshaking and turn speaker off while receiving carrier.  
Turn speaker on during handshaking and while receiving carrier.  
Turn speaker off during dialing and receiving carrier speaker on during answering.  
Turn off automode detection.  
Turn on automode detection.  
Go on-line.  
Go on-line and initiate a retrain sequence.  
Force pulse dialing.  
Q0  
Q1  
Sn  
Sn?  
=v  
Allow result codes to DTE.  
Inhibit result codes to DTE.  
Select S register as default.  
Return the value of S register n.  
Set default S register to value v.  
- 34 -  
 
APPENDIX A  
?
T
Return the value of default S register.  
Force DTMF dialing.  
V0  
V1  
W0  
W1  
W2  
X0  
X1  
Report short form (terse) result codes.  
Report long form (verbose) result codes.  
Report DTE speed in EC mode.  
Report line speed, EC protocol and DTE speed.  
Report DCE speed in EC mode.  
Report basic call progress result codes, i.e., OK, CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO ANSWER and ERROR.  
Report basic call progress result codes and connections speeds (OK, CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO ANSWER,  
CONNECT XXXX, and ERROR.  
X2  
Report basic call progress result codes and connections speeds, i.e., OK, CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO  
ANSWER, CONNECT XXXX, and ERROR.  
X3  
Report basic call progress result codes and connection rate, i.e., OK, CONNECT, RING, NO CARRIER, NO ANSWER, CONNECT XXXX, BUSY, and ERROR.  
X4  
Report all call progress result codes and connection rate, i.e., OK, CONNECT, RING, NO CARRIER, NO ANSWER, CONNECT XXXX, BUSY, NO DIAL TONE and ERROR.  
Y0  
Y1  
Z0  
Z1  
&C0  
&C1  
&D0  
&D1  
&D2  
&D3  
&F  
Disable long space disconnect before on-hook.  
Enable long space disconnect before on-hook.  
Restore stored profile 0 after warm reset.  
Restore stored profile 1 after warm reset.  
Force RLSD active regardless of the carrier state.  
Allow RLSD to follow the carrier state.  
Interpret DTR ON-to-OFF transition per &Qn.  
Interpret DTR ON-to-OFF transition per &Qn.  
Interpret DTR ON-to-OFF transition per &Qn.  
Interpret DTR ON-to-OFF transition per &Qn.  
Recall (restore) factory profile.  
&G0  
&G1  
&G2  
&J0  
&J1  
&K0  
&K3  
&K4  
&L0  
&L1  
&M0  
&M1  
&M2  
&M3  
&P0  
&P1  
&P2  
&P3  
&Q0  
&Q1  
&Q2  
&Q3  
&Q4  
&Q5  
&Q6  
Disable guard tone.  
Disable guard tone.  
Enable 1800 Hz guard tone.  
Set S register response only for compatibility.  
Set S register response only for compatibility.  
Disable DTE/DCE flow control.  
Enable RTS/CTS DTE/DCE flow control.  
Enable XON/XOFF DTE/DCE flow control.  
Select dial up line operation.  
Select leased line operation.  
Select direct asynchronous mode.  
Select sync connect with async off-line command mode.  
Select sync connect with async off-line command mode and enable DTR dialing of directory zero.  
Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch.  
Set 10 pps pulse dial with 39%/61% make/break.  
Set 10 pps pulse dial with 33%/67% make/break.  
Set 20 pps pulse dial with 39%/61% make/break.  
Set 20 pps pulse dial with 33%/67% make/break.  
Select direct asynchronous mode.  
Select sync connect with async off-line command mode.  
Select sync connect with async off-line command mode and enable DTR dialing of directory zero.  
Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch.  
Select Hayes AutoSync mode.  
Modem negotiates an error corrected link.  
Select asynchronous operation in normal mode.  
- 35 -  
 
APPENDIX A  
&R0  
&R1  
&S0  
&S1  
&T0  
&T1  
&T2  
&T3  
&T4  
&T5  
&T6  
&T7  
&T8  
&V  
CTS tracks RTS (async) or acts per V.25 (sync).  
CTS is always active.  
DSR is always active.  
DSR acts per V.25.  
Terminate any test in progress.  
Initiate local analog loopback.  
Returns ERROR result code.  
Initiate local digital loopback.  
Allow remote digital loopback.  
Disallow remote digital loopback request.  
Request an RDL without self-test.  
Request an RDL with self-test.  
Initiate local analog loop with self-test.  
Display current configurations.  
&W0  
&W1  
&X0  
&X1  
&X2  
&Y0  
&Y1  
&Zn=x  
%E0  
%E1  
%E2  
%L  
Store the active profile in NVRAM profile 0.  
Store the active profile in NVRAM profile 1.  
Select internal timing for the transmit clock.  
Select external timing for the transmit clock.  
Select slave receive timing for the transmit clock.  
Recall stored profile 0 upon power up.  
Recall stored profile 1 upon power up.  
Store dial string x (to 40) to location n (0 to 19).  
Disable line quality monitor and auto retrain.  
Enable line quality monitor and auto retrain.  
Enable line quality monitor and fallback/fall forward.  
Return received line signal level.  
Report the line signal quality.  
%Q  
%TTn  
\G0  
\G1  
\Kn  
\N0  
PTT certification test signals.  
Disable modem to modem flow control.  
Enable modem to modem flow control.  
Controls break handling during three states.  
Select normal speed buffered mode.  
Select direct mode.  
\N1  
\N2  
Select reliable link mode.  
\N3  
Select auto reliable mode.  
\N4  
Force LAPM mode.  
\N5  
Force MNP mode.  
ECC COMMANDS  
%C0  
%C1  
%C2  
%C3  
\A0  
\A1  
\A2  
\A3  
\Bn  
Disable data compression.  
Enable MNP 5 data compression.  
Enable V.42 bis data compression.  
Enable both V.42 bis and MNP 5 compression.  
Set maximum block size in MNP to 64.  
Set maximum block size in MNP to 128.  
Set maximum block size in MNP to 192.  
Set maximum block size in MNP to 256.  
Send break of n x 100 ms.  
\L0  
Use stream mode for MNP.  
\L1  
Use block mode for MNP.  
- 36 -  
 
EXP Fax/Data Modem  
OPERATING CONSIDERATION  
MNP 10 COMMANDS (14.400 modem only)  
)M0  
)M1  
Disable MNP 10 link negotiation power adjustment.  
Enable MNP 10 link negotiation power adjustment.  
*H0  
*H1  
*H2  
-K0  
Select MNP 10 link negotiation at highest rate.  
Select MNP 10 link negotiation at 1200 bps.  
Select MNP 10 link negotiation at 4800 bps.  
Disable MNP 10 extended services.  
-K1  
Enable MNP 10 extended services.  
-K2  
-Q0  
-Q1  
@M0  
@M1  
@M2  
@M3 - @M10  
@M11  
@M12  
.
Enable MNP 10 extended services detection only.  
Disable MNP 10 fallback to 2400 bps (V.22 bis)/1200 bps (V.22).  
Enable MNP 10 fallback to 2400 bps (V.22 bis)/1200 bps (V.22).  
Select initial transmit level of -26 dBm.  
Select initial transmit level of -30 dBm.  
Select initial transmit level of -10 dBm.  
Select initial transmit level of -10 dBm.  
Select initial transmit level of -11 dBm.  
Select initial transmit level of -12 dBm.  
.
.
@M30  
@M31  
:E0  
Select initial transmit level of -30 dBm.  
Select initial transmit level of -31 dBm.  
Disable the compromise equalizer.  
Enable the compromise equalizer.  
:E1  
- 37 -  
 
APPENDIX B  
APPENDIX B  
S REGISTERS  
The S registers are summarized in table along with their default values. Registers denoted with an '*' in the table may be stored in one of the two user profiles by entering the &Wn command. One of these  
profiles may be loaded at any time by using the Zn command. Registers or register fields quoted as "reserved" are reserved for current or future use by the firmware, or are permanently overridden by PTT  
limitations.  
All bit-mapped registers are read-only. The appropriate AT command which controls the relevant bits in the S-register should be used to change the value.  
FACTORY DEFAULTS  
The factory default values are stored in ROM and are loaded into the active configuration at power up or by the AT&F command. In addition, the designated default profile is subsequently loaded, and may  
change some of the factory default values. The designated default profile can be changed by entering the &Yn command where n is one of the two possible user profiles.  
The defaults shown are those used in factory profile. All of the factory default values may be loaded at any time by entering the &F command.  
S Register Summary.  
Register  
S0  
Function  
Rings to Auto-Answer  
Ring Counter  
Range Units  
Save  
Default  
0-255  
0-255  
0-255  
0-127  
0-127  
0-255  
2-255  
1-255  
0-255  
rings  
*
0
0
S1  
rings  
ASCII  
ASCII  
ASCII  
ASCII  
s
S2  
Escape Character  
*
43  
13  
10  
8
S3  
Carriage Return Character  
Line Feed Character  
Backspace Character  
Wait Time for Dial Tone  
Wait Time for Carrier  
S4  
S5  
S6  
*
*
*
4
S7  
s
50  
2
S8  
Pause Time for Dial Delay  
Modifier  
s
S9  
S10  
Carrier Detect Response Time  
Carrier Loss Disconnect Time  
DTMF Tone Duration  
1-255  
1-255  
0.1s  
0.1s  
*
6
14  
*
S11  
50-255 0.001 s  
*
Save  
*
95  
Register  
S12  
Function  
Range  
Units  
Default  
50  
Escape Code Guard Time  
0-255  
0.02 s  
- 38 -  
 
APPENDIX B  
S13  
S14  
S15  
S16  
Reserved  
-
-
-
-
-
-
-
-
-
*
-
General Bit Mapped Options  
Reserved  
138 (8Ah)  
-
Test Mode Bit Mapped  
Options(&T)  
0
S17  
S18  
S19  
S20  
Reserved  
-
-
-
0
-
Test Timer  
0-225  
-
s
-
*
-
-
AutoSync Bit-Mapped Options  
HDLC address or BSC sync  
character  
0-255  
ASCII  
-
S21  
S22  
S23  
V.24/General Bit Mapped  
Options  
-
-
-
-
-
*
*
4(04h)  
117(75h)  
55(37h)  
Speaker/Results Bit Mapped  
Options  
General Bit Mapped Options  
-
S24  
S25  
Sleep Inactivity Timer  
Delay to DTR Off  
0-255  
0-255  
s
0
5
s or  
0.01s  
S26  
S27  
RTS-to-CTS Delay  
0-255  
-
0.01s  
-
1
General Bit Mapped Option  
*
*
73(49h) w/ ECC  
74(4Ah)w/o ECC  
S28  
S29  
S30  
S31  
General Bit-Mapped Options  
Flash Dial Modifier Time  
-
-
10 ms  
10s  
-
0
0
0
2
0-255  
0-255  
-
Disconnect Inactivity Timer  
General Bit-Mapped Options  
*
S32  
XON Character  
0-255  
ASCII  
17 (11h)  
Register Function  
Range  
Units  
Save  
Default  
- 39 -  
 
APPENDIX B  
S33  
XOFF Character  
0-255  
ASCII  
19 (13h)  
S34-S35 Reserved  
-
-
-
S36  
S37  
S38  
S39  
S40  
S41  
LAPM Failure Control  
-
-
-
7
Line Connection Speed  
Delay Before Forced Hang-up  
Flow Control  
-
-
*
0
0-255  
s
20  
-
-
*
*
*
3
General Bit-Mapped Options  
General Bit-Mapped Options  
-
-
107(6Bh)  
-
-
3
S42-S45 Reserved  
-
-
-
S46  
S48  
S80  
S82  
S86  
S91  
Data Compression Control  
-
-
*
*
-
13  
V.42 Negotiation Control  
Soft-Switch Functions  
LAPM Break Control  
-
-
7
-
-
-
0
-
-
128(40h)  
Call Failure Reason Code  
0-255  
0-15  
-
PSTN Transmit Attenuation  
Level  
dBm  
10  
S92  
S95  
Fax Transmit Attenuation Level  
Result Code Messages Control  
Leased Line Transmit Level  
Cellular Transmit Level  
0-15  
-
dBm  
-
10  
0
*
S99  
0-15  
-dBm  
10  
S201  
S202  
*
*
Remote Access Escape  
0-255  
ASCII  
170  
C
h
a
r
a
c
t
e
r
* Register value may be stored in one of two user profiles with the &W command.  
- 40 -  
 
APPENDIX B  
- 41 -  
 
 
FCC  
FCC COMPLIANCE STATEMENTS  
FCC Part 68  
This equipment complies with Part 68 of FCC rules. On the Fax/Data modem there is a label that contains, among other information, the FCC registration number and Ringer Equivalence Number(REN) for  
the equipment. If requested, please provide this information to your telephone company.  
The REN is useful to determine the maximum number of devices may be able to ring when your number is called. In most, but not all areas, the sum of the RENs of all devices should not exceed five(5.0). To  
be certain of the number of the devices you may connect to your line, please call your local telephone company.  
If your Fax/Data Modem is seemed to cause harm to the telephone network, your telephone company may discontinue your service temporarily. If possible, they will notify you in advance. But if advance notice  
isn't practical, you will be notified as soon as possible. You will be advised of your right to file a complaint with the FCC.  
Your telephone company may make changes in its facilities, equipment, operation, or procedures that could affect the proper operation of your equipment. If they do, you will be given advance notice so as to give  
you an opportunity to maintain uninterrupted service.  
If you experience trouble with the Fax/Data Modem, please contact your dealer for repair/warranty information. The telephone company may ask you to disconnect this equipment from the network until the  
problem has been corrected or you are sure that the equipment is not malfunctioning. There are no repaired that can be made by the customer to the Fax/Data Modem. All repairs need to be made by Modem  
manufacture.  
This equipment may not used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. (Contact you state public utility commission or corporation commission for  
information).  
- 43 -  
 
FCC  
FCC Part 15  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against  
harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful  
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,  
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the distance between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
CAUTION: CHANGE OR MODIFICATIONS NOT EXPRESSLY APPROVED BY PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT.  
- 44 -  
 
FCC  
CONSUMER INFORMATION AND FCC REQUIREMENTS  
The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other electronic device to send any message via a telephone fax machine unless such message clearly  
contains in a margin at the top or bottom of each transmitted page or on the first page of the transmission, the date and time it is sent and an identification of the business or other entity, or other individual  
sending the message and the telephone number of the sending machine or such business, other entity, or individual.  
In order to program this information into your fax machine, you should complete the following steps:  
A. If you modem is ThinFax 1414LX or ThinFax 1414 LXM, and is using MiniFax as your fax software, please use the following procedure. Otherwise skip to (B):  
(1) Under your System Manager Menu, select Setup, Option then Date to enter the date and time information.  
(2) In your MiniFax Software, go to the Configuration Menu and enter all the information into the menu, then click the OK button.  
The MiniFax software will generate the required headers on the fax page.  
B. If your modem is ThinFax 288i, ThinFax 288c ThinFax 1414i, ThinFax 1414c, ThinFax 1414CL, ThinFax 1414LX , ThinFax 1414LXM, or the modem portion of the ThinCom and is using QuickLink II Fax  
software  
(1) Under your Windows environment, go through Main-Control Panel-Date/Time to enter the date and time information.  
(2) Go to the Cover Page Setup section of your QuickLink II Fax software, enter information about you and your company for the fax page headers and click the OK button when all of the information  
are completed.  
The QuickLink II Fax software will generate the required headers on the fax page according to the information entered in the Cover Page Setup. If you need to know more detail about how to use the  
setup, please consult the Cover Page Setup section of your QuickLink II Fax software Users Guide.  
- 45 -  
 
FCC  
Canadian Department of Communications compliance statements  
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications.  
NOTICE: The Canadian Department of Communication label identifies certified equipment. This certification means that the equipment meets certain telecommunication network protective, operational, and  
safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction.  
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using acceptable  
method of connection. In some cases, the company's inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The  
customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.  
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment malfunctions, may give  
the telecommunications company cause to request the user to disconnect the equipment.  
Users should ensure, for their own protection, that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together. This  
precaution may be particularly important in rural areas.  
Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.  
The "Load Number" (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on  
the loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all device does not exceed 100.  
- 46 -  
 
 
 
 

Dyson Vacuum Cleaner DC08 User Manual
EAW Speaker SB48zP User Manual
Ford Automobile 2010 Mustang User Manual
GE Clothes Dryer PFDS450EL User Manual
GE Microwave Oven JE510 User Manual
Generac Portable Generator 5940 User Manual
Genicom Printer 140 TM User Manual
Gitzo Camcorder Accessories G1345 User Manual
Glen Dimplex Home Appliances Ltd Cooktop 100 E User Manual
Global Machinery Company Saw LS1375 User Manual